Timber Structures

Simple prescriptive rules for fire design of timber members are available in the following references:
  • BS5268-4.1 (1978) – For timer members
  • BS5268-4.2 (1990) – For timber stud walls & joisted floor constructions
  • EN1995-1-2 (2004) – For general timber structures
  • BRE Report 128 (1988) – For timber floors

In general, the design codes adopt the concept of calculating timber member strengths on a residual non-charred section with the charred portion considered as having no strength. The rules for determining the charring depths are based on the standard fire tests.

It is noteworthy that a large number of the standard fire tests carried out to determine the rates of charring have been conducted on panels subjected to a single face heating in a small furnace, rather than on full-scale timber elements subjected to multi-face heating in a normal size furnace (Purkiss 1996). As a result, the charring rates obtained from the tests cannot accurately represent the actual charring conditions of beam and column members because the members’ geometry and the heat flux on the members are quite different.

To take into account the increased rate of charring on multi-face fire exposure, BS5268-4.1 makes the following assumptions:

  • Arrises will become progressively rounded during fire exposure (see Figure 1).
  • Rates of charring for columns exposed to fire on all faces are 25% higher than those for beams.
Such compensating approaches are not adopted in prEN1995-1-2. However, prEN1995-1-2 introduces the concept of effective charring depth def as shown in Figure 2. In addition to the charring depth dchar obtained from the standard fire tests, the constant d0 = 7mm is calibrated from the tests. The coefficient k0 (= 1.0) depends on the factors such as the surface protection and the required fire resistance duration.



Figure 1 Radius of Arris Rounding according to BS5628-4.1
Figure 2 Effective Charring Depth according to EN1995-1-2

The use of charring depths is suitable for large section timber which will perform well in a fire. For smaller section timber, protection from linings is required. For instance, prEN1995-1-2 states that in the walls and floors construction, timber frame members with dimensions less than 38mm should be protected by claddings throughout the required fire resistance time. Care is required in ensuring the quality of fixings of the protecting lining to the supporting timber on site, which must be the same quality as the fixings used in the standard fire tests, from which the tables were derived.

Tabular data

In the case of walls and floors, BS5268-4.2 provides the tabulated data for various fire resistance periods in stability, integrity and insulation including:

The tabulated data are limited to a fire resistance of 1 hour or less, considering different joist sizes, floor boarding and ceiling protection. The dimension limits include:

  • For loadbearing walls and partitions, the actual stud sizes > 62mm × 37mm (depth × breadth) (see Figure 3)
  • For non-loadbearing walls and partitions, the actual stud sizes > 48mm × 37mm (depth × breadth)
  • For joisted floors, the actual joist breadth > 37mm (see Figure 3)
Figure 3 Dimensions of Stud and Joist according to BS5628-4.2

In practice, timber structures are generally designed and built in simple construction method, such as simply supported beams and pin jointed triangulated trusses. The structural connections can be in forms of nails, bolts, timber connectors and embedded steel connecting plates. Special consideration is required in ensuring the connection and detailing to achieve fire resistance particularly with connections that transfer forces from one member to another. Basically, charring of heated members may alter the relative stiffness of various parts of a structure, and result in a redistribution of forces. The redistribution of forces may cause the yielding of connections made from metal fasteners and components.

Where any part of a nail, screw or bolt is exposed to heating during a fire, rapid heat conduction will lead to localized charring and loss of anchorage. If this effect is likely to lead to the failure of a structural member which is required to have fire resistance, BS5268-4.1 requests the fastener to be fire protected. For timber construction with no fire resistance requirements, metal connectors and components can be used without restriction. PrEN1995-1-2 takes the inherent fire resistance of various connections as the minimum fire resistance. To achieve a fire resistance more than the minimum value, depending on the types of connection, the extra fire protection can be provided by:

  • Specifying extra cladding to metal fasteners or increasing edge distances to fasteners
  • Increasing the number of fasteners or choosing stronger fasteners.