You are here: Home > Design >
Performance >
Thermal Analyses >
DesignFormulae >
default.htm
|
|
FAQ Events |
|
|
Design Formulae
|
|
There are only a few of design formulae for calculating
the temperature response of steel and concrete members. It should
be noted that the formulae are only valid for the prediction of
thermal response to the heating conditions upon which the formulae
are derived. In most cases, the formulae have been empirically
derived from the standard fire tests. As a result, designers are
often unable to apply the formulae to their particular design with
different heating conditions, for example in case of a natural
fire.
The main assumption in the design formulae for
calculating the temperature response of structural members is that
the member boundaries are not subject to any possible changes during
the fire exposure, except for a partial or total loss of the insulation
for steelwork. The temperature rise of steelwork is normally calculated
at small time steps and the temperature rises are accumulated after
each time step until the end of fire exposure. The loss of insulation
can easily be considered in the analytical procedure by changing
the boundary conditions at any specified time step and onwards.
However, to date, the spalling of concrete cannot
be incorporated in any simple calculation formulae since the mechanism
of spalling is very complicated and difficult to be quantified.
For concrete members, spalling of concrete cover can occur during
a fire exposure reducing the cross section of the member and exposing
the reinforcement to the fire, resulting in a greater loss in strength.
Without considering spalling, the calculation of the thermal response
will tend to be less conservative and may lead to unsafe design
in the structural response.
There are simple design formulae available for
calculating the thermal response of the following structural members:
- Unprotected steel members
- Protected steel members
- Unprotected composite slabs
- Concrete members
|
|
|
|
|
| |
|
|
|